Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractAbundant oxygenated volatile organic compounds and their contribution to photochemical pollution in subtropical Hong Kong    Next AbstractMajor urinary protein-1 increases energy expenditure and improves glucose intolerance through enhancing mitochondrial function in skeletal muscle of diabetic mice »

Environ Monit Assess


Title:Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong
Author(s):Hui PS; Mui KW; Wong LT;
Address:"Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China"
Journal Title:Environ Monit Assess
Year:2008
Volume:20071101
Issue:1-Mar
Page Number:315 - 322
DOI: 10.1007/s10661-007-9994-6
ISSN/ISBN:0167-6369 (Print) 0167-6369 (Linking)
Abstract:"It is costly to sample all air pollutants of a general community. Air sampling should be conducted based on a practical assessment strategy and monitoring plan. In Hong Kong, the Environmental Protection Department (HKEPD) launched an Indoor Air Quality (IAQ) certification scheme to grade workplace IAQ as 'Excellent' or 'Good' by measuring the levels of nine common indoor air pollutants, namely carbon dioxide (CO(2)), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO(2)), ozone (O(3)), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), and airborne bacteria count (ABC). Although average office IAQ performance has been improved since the implementation of this certification scheme, there are still resource issues and technical difficulties. To streamline the assessment of office IAQ performance, this study proposes a simple index of IAQ benchmarks formulated in compliance with the HKEPD requirements. In particular, three of the nine listed common air pollutants were selected as the 'representatives' for the overall satisfactory IAQ. Together with the assessment results of 422 Hong Kong air-conditioned offices, the index was evaluated in terms of test sensitivity, specificity and predictive values. Proved to be feasible to describe the IAQ of some air-conditioned offices, this IAQ index would be a useful tool for policymakers, building owners and professionals to quantify IAQ performance in offices and to make decisions on resources and manpower management for efficient mitigation actions"
Keywords:"*Air Conditioning Air Pollutants/*analysis Air Pollutants, Occupational/*analysis Air Pollution, Indoor/*analysis Environmental Exposure *Environmental Monitoring/methods/standards Hong Kong Humans Inhalation Exposure *Workplace;"
Notes:"MedlineHui, Pui-Shan Mui, Kwok-Wai Wong, Ling-Tim eng Research Support, Non-U.S. Gov't Netherlands 2007/11/02 Environ Monit Assess. 2008 Sep; 144(1-3):315-22. doi: 10.1007/s10661-007-9994-6. Epub 2007 Nov 1"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 29-06-2024