Bedoukian   RussellIPM   RussellIPM   Piezoelectric Micro-Sprayer


Home
Animal Taxa
Plant Taxa
Semiochemicals
Floral Compounds
Semiochemical Detail
Semiochemicals & Taxa
Synthesis
Control
Invasive spp.
References

Abstract

Guide

Alphascents
Pherobio
InsectScience
E-Econex
Counterpart-Semiochemicals
Print
Email to a Friend
Kindly Donate for The Pherobase

« Previous AbstractCatalytic ozonation of methylethylketone over porous Mn-Cu/HZSM-5    Next AbstractOdorant and pheromone receptors in insects »

Chemosphere


Title:The feasibility and temporal storability of gas phase standards of volatile organic compounds prepared through liquid phase vaporization in polyester aluminum bags at room temperature
Author(s):Ha SH; Szulejko J; Kim KH;
Address:"Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul, 04763, Republic of Korea. Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul, 04763, Republic of Korea. Electronic address: kkim61@hanyang.ac.kr"
Journal Title:Chemosphere
Year:2022
Volume:20211118
Issue:Pt 2
Page Number:132965 -
DOI: 10.1016/j.chemosphere.2021.132965
ISSN/ISBN:1879-1298 (Electronic) 0045-6535 (Linking)
Abstract:"Currently, the presence of many classes of volatile organic compounds (VOCs) in indoor air is well recognized. There is an impetus to accurately quantify airborne VOCs for the proper assessment of their human health risks. VOC standards prepared in a solvent are often vaporized in N(2) gas-filled sampling bags for external calibration as the use of grab sampling bags is a common practice for the collection of real ambient air samples. Such practices can nontheless be subject to many sources of biases in their calibration (e.g., VOC chemical reaction with the solvent, adsorption on the bag interior surface, or leakage). The main goal of this work is to measure the temporal stability of 11 VOC targets (benzene, toluene, o-xylene, styrene, propionaldehyde, n-butyraldehyde, isovaleraldehyde, valeraldehyde, acrylonitrile, isoprene, and methyl ethyl ketone) selected in this research over 24 h which started 10 min after the injection and vaporization of liquid-phase standards (all prepared in methanol solvent) into polyester aluminum (PEA) bags containing 1 atm N(2). Although all tested VOCs showed gradual decreases of their concentrations (e.g., >17% in 24 h), the aromatic hydrocarbon VOCs (namely BTXS) yielded the best relative recoveries (e.g., decreases of 11%-30% in 24 h) and relative errors (e.g., relative standard error (RSE) = 2.14-3.59%) in 5 replicate tests. A good linear relationship was established between the 24 h VOC relative recovery and molecular weight (R(2) > 0.81). The results of this study offers valuable clues to properly reduce the bias in the calibration of gas-phase VOC standards when calibrating the system through the vaporization of liquid-phase VOC standards prepared in a solvent"
Keywords:*Air Pollutants/analysis Aluminum Environmental Monitoring Feasibility Studies Humans Polyesters Temperature *Volatile Organic Compounds/analysis Volatilization Air sampling Polyester aluminum bag Response factor Storage stability Vaporization Volatile or;
Notes:"MedlineHa, Seung-Ho Szulejko, Jan Kim, Ki-Hyun eng England 2021/11/22 Chemosphere. 2022 Mar; 291(Pt 2):132965. doi: 10.1016/j.chemosphere.2021.132965. Epub 2021 Nov 18"

 
Back to top
 
Citation: El-Sayed AM 2024. The Pherobase: Database of Pheromones and Semiochemicals. <http://www.pherobase.com>.
© 2003-2024 The Pherobase - Extensive Database of Pheromones and Semiochemicals. Ashraf M. El-Sayed.
Page created on 18-06-2024